The ACFC gas-liquid two-phase flowmeter adopts the measurement principle of "gas-liquid component+ultrasonic+differential pressure". The product composition includes: flow integrator, ultrasonic data processing unit, ultrasonic sensor, temperature and pressure sensor, throttling element, differential pressure sensor, gas-liquid component measurement unit, etc.
project | Technical Specifications |
Nominal Diameter | routine DN50/DN80 |
measurement range | Gas phase maximum 100000 Nm ³/d (customizable) Liquid phase maximum 480m ³/d (customizable) |
Single phase accuracy | Gas phase 1.0, liquid phase 1.5 |
| Mixing error | Low water content (<20%) mixing error ≤± 7% mixing error ≤± 10% High water content (≥ 20%) mixing error ≤± 10% mixing error ≤± 20% |
turndown ratio | Mixed flow ratio greater than 1:40 |
Liquid resolution | ±0.1% |
communication protocol | Modbus RTU agreement |
output signal | RS485 |
Explosion-proof rating | Ex db ia (ia Ga) IIC T4 Gb |
Protection level | IP65 |
Operating Temperature | (-40~70)℃ |
power supply | Wide voltage power supply(11~30)VDC |
Nominal Pressure | routine 6.3/10/16(MPa) |
output data | Instantaneous cumulative flow rate of gas, instantaneous cumulative flow rate of liquid, moisture content, differential pressure, temperature, static pressure |