Products & Solutions

Products and Solutions

ACFC Ultrasonic Flowmeter

ACFC natural gas metering system
ACFC natural gas metering system

ACFC natural gas metering system

The natural gas metering system is a system used to achieve the measurement of natural gas transfer, applied to long-distance natural gas pipelines, trade transfer at urban gate stations, and other occasions that require high-precision measurement, to achieve high-precision and high stability measurement of natural gas volume flow rate and energy flow rate.

ANCN Smart ACFC Natural Gas Metering System is designed according to GB/T18603 "Technical Requirements for Natural Gas Metering Systems". It relies on its own advanced and mature gas ultrasonic flowmeter products, equipped with high-precision pressure transmitters, temperature transmitters, flow computers, and flow computer control cabinets. Through personalized customization, it provides users with high-precision, high stability, reasonable layout, and compact metering system products and technical services.


Main Features

serial numberDetailed features
1Dual redundancy design (instrument inspection and maintenance without shutdown)
2Minimum support for DN50 caliber
3Compact structure and high integration, in addition to integrating measurement related instruments, it can also integrate equipment such as valves, filters, and heat tracing
4The measuring instruments can be selected from ACFC-D and ACFC-I, and other brands can also be customized
5Scalable support for accessing gas chromatography to achieve natural gas energy metering
6Support personalized customization to meet the characteristics of different venues, working conditions, and other special user needs

Specifications

project

Technical Specifications

Caliber range

DN50~DN300

pressure range

(0~16)MPa

measuring medium

Natural gas, coalbed methane

Measuring flow velocity

 range

(0.3~30)m/s

Environmental

 temperature for use

(-40~+70)℃

System accuracy level

A-level

Flow measurement instrument

Measuring principle

Time difference method gas ultrasonic flowmeter

accuracy class

Optional level 0.5 or 1.0

Pressure transmitter

Superior to level 0.075

Temperature Transmitter

Superior to level 0.2

communication interface

RS485/RS232、LAN、USB( Diagnosis and Debugging )

Input signal interface

Pulse (high frequency, low frequency), 4-20mA analog quantity (supporting Hart protocol), digital quantity (status indication)

Length of straight

 pipe section

10D+5D

Type of rectifier

Plate rectifier (optional)

Pipe material

carbon steel /304/316

Cabinet power supply

AC220 或 DC24V