Products & Solutions

Products and Solutions

pressure

Digital differential pressure transmitter ACD-3151
Digital differential pressure transmitter ACD-3151
Digital differential pressure transmitter ACD-3151

Digital differential pressure transmitter ACD-3151

The ACD-3151 digital differential pressure transmitter is a new type of digital differential pressure instrument independently developed and produced by Ansen Instrument based on the introduction of advanced foreign technology. It applies Ansen Instrument's advanced micro power consumption technology and software compensation technology. Key components and parts are imported, and the whole machine undergoes strict assembly, testing, and aging to ensure the quality of the instrument.


This product has the characteristics of advanced design, complete variety and specifications, and easy installation and use. At the same time, it can be directly replaced with traditional 1151, 3051 and other series products during installation, making it a replacement and updated product for some old models. In order to adapt to the continuous improvement and development of domestic automation level, this series of products not only have a compact and exquisite design, but also have the function of on-site pressure display.


Main Features

display unit

Pa , kPa , MPa , psi , bar , mbar , kgf/cm2 , inH2O , mmH2O, inHg, mmHg

 

measurement range

differential pressure :0~1kPa至0~4MPa

accuracy class

0.05 level, 0.075 level, 0.1 level, 0.2 level

stable performance

Better than 15 years ± 0.2% URL

output signal

(4-20) mA (24V DC, two-wire system)

contact method

HART、RS485

power supply method

(10-30) V DC (communication power supply)

Collection speed

(0.1~10) seconds/time, default 0.2 seconds/time, time can be set independently

ambient temperature

(-40~85)℃  
(-30~80) ℃ with LCD meter head

relative humidity

<90%

atmospheric pressure

(86~106)kPa

other

Calibrate the reference environment temperature :20℃±2℃

Instrument operating environment temperature at level 0.075 :(0~50)℃  

Measure the temperature of the medium

Conventional: (-40~85) ℃
Wide temperature: (-70~400) ℃ Flange installation filled with high-temperature silicone oil

display mode

Five digit backlit display+percentage bar chart; Digital header with setting button; No header

Protection level

IP65 / IP66 / IP67

Explosion-proof rating

ExdIICT6 Gb   

Overload pressure

Maximum static pressure: 32MPa
Unidirectional maximum overload pressure: 32MPa
Bidirectional maximum overload pressure: 48MPa  Note: Overload pressure depends on the range of measurement

software configuration

AncnView-TIntelligent instrument 

detection software (with RS485 communication): 

Real time display of instrument data, 

automatic recording, 

automatic drawing of pressure curves, 

can be exported to Excel spreadsheets

 for reading, printing, and saving。    

process connection

Public  Manufacturing: M20 × 1.5, M14 × 1.5, M14 × 1, etc.
English/American standards: G1/2, G3/4, G1/8, G3/8
NPT 1/2, NPT 1/4, NPT 1/8, etc.