The ACD-2H standard digital pressure gauge adopts advanced micro power consumption, high-precision devices, and complete embedded software technology. The instrument adopts temperature dynamic compensation technology, which can ensure that the instrument accuracy level can be met in the full temperature range. It is equipped with high-performance industrial lithium batteries and can work continuously for 10 years under normal conditions. The standard signal is fully isolated RS485 communication interface. When there is external power, it can directly communicate with the computer through communication software. The communication software has processing functions such as data acquisition, curve, storage, and reporting.
| Pa , kPa , MPa , psi , bar , mbar , kgf/cm2 , inH2O , mmH2O, inHg, mmHg |
measurement range | gauge pressure:-0.1MPa~0MPa~...~260MPa |
accuracy class | 0.05 level, 0.1 level |
contact method | RS485、USB |
power supply method | foreign news reports:(10~30)Vdirect currentInternal electricity:Built in 1 3.6V high-performance lithium battery |
Collection speed | (0.25~10) seconds/time, default 0.5 seconds/time, time can be set |
stable performance | Better than 0.1% FS/year; |
Battery working time | Built in 3.6V high-performance lithium battery, reference conditions: (16-25) ℃
|
ambient temperature | (-30~70)℃ |
relative humidity | <90% |
atmospheric pressure | (86~106)kPa |
other | Calibration reference environment temperature: 20 ℃± 2 ℃ Instrument working environment temperature at level 0.05: (0-50) ℃ |
Measure the temperature of the medium | 常规(-40~120)℃ |
display mode | Six digit display+percentage bar chart |
Protection level | IP65 |
Explosion-proof rating | Ex ia IIC T4 Ga |
Overload pressure | 1.5 to 3 times the measuring range, depending on the measurement range |
process connection | Metric system: M20 × 1.5, M14 × 1.5, M14 × 1, etc English/American standards: G1/2, G3/4, G1/8, G3/8 NPT 1/2, NPT 1/4, NPT 1/8, etc |