ACD-LR wireless digital pressure transmitter is a newly designed sanitary pressure instrument specifically designed for the food and pharmaceutical industry. The contact part between the instrument and the process medium is made of high-quality 316L stainless steel and ceramic material structure. The installation method adopts international standard process connection installation interfaces such as clamps and quick and convenient connectors that meet hygiene standards. It is very suitable for CIP/SIP in-situ cleaning and sterilization and external water spray cleaning operations, solving problems such as scaling, blockage, cleaning and hygiene. It has the advantages of quick and convenient installation and disassembly on the process site, not easy to contaminate, easy to clean, safe and reliable.
The ACD-LR wireless digital pressure transmitter mainly consists of a pressure sensor, signal processing circuit, central processing unit, and wireless communication circuit. Equipped with advanced low-power devices and sophisticated software management technology, it is powered by a large capacity high-performance lithium battery with a lifespan of 3-5 years. Realize remote real-time monitoring, wireless transmission, no need for on-site wiring, saving the trouble of on-site wiring for ordinary instruments, and saving manpower and construction costs. This instrument has advanced design, complete variety and specifications, and is easy to install and use, making it an ideal upgraded product for traditional pressure transmitters.
Display Unit | Pa , kPa , MPa , psi , bar , mbar , kgf/cm2 , inH2O , mmH2O, inHg, mmHg |
Measurement Range | Gauge pressure: -0.1MPa~0~...~7MPa |
Accuracy | 0.05% / 0.1% / 0.2% / 0.5% |
Power Supply | Built in 3.6V high-performance lithium battery |
Sample Duration | (1~60) seconds/time, default 5 seconds/time, configurable |
Stability | Better than 0.1% FS/year |
Battery | Built in 3.6V high-performance lithium battery, reference conditions: (16-25) ℃ |
| Sampling Frequency | Once per second; 1 time/2 seconds 1 time/3 seconds 1 time/4 seconds |
Battery Life | 3 years |
Ambient Temperature | (-30 ~ 70)℃ |
Relative Humidity | < 90% |
Atmospheric Pressure | (86 ~ 106)kPa |
Other | Calibration reference environment temperature: 20 ℃± 2 ℃ |
Process Temperature | (-40 ~ 120)℃ |
Display | Five digit display+percentage bar chart |
Protection Rating | IP65 |
EX-proof Rating | Ex ia IIC T4 Ga |
Overload | 1.5 to 3 times the measuring range, depending on the measurement range |
Process Connection | Clamp, quick chuck, customized interface |