The ACD-302 pressure transmitter is a newly designed sanitary pressure instrument specifically designed for the food and pharmaceutical industry. The contact part between the instrument and the process medium is made of high-quality 316L stainless steel and ceramic material structure. The installation method adopts international standard process connection installation interfaces such as clamps and quick and convenient connectors that meet hygiene standards. It is very suitable for CIP/SIP in-situ cleaning and sterilization as well as external water spray cleaning operations, solving problems such as scaling, blockage, cleaning and hygiene. It has the advantages of quick and convenient installation and disassembly on the process site, not easy to contaminate, easy to clean, and safe and reliable safety.
The ACD-302 pressure transmitter is a new product independently developed by our company based on our previous product technical experience. The instrument not only has the (4-20) mA analog signal output function of the transmitter, but also can add RS485 digital communication function; Can be used in conjunction with communication software to directly collect data from computers or other communication interfaces, and to save, process, and output detection data in reports; The instrument adopts advanced low-power devices and sophisticated software technology; It has a rare five digit LCD backlight display for pressure transmitters.
display unit | Pa , kPa , MPa , psi , bar , mbar , kgf/cm2 , inH2O , mmH2O, inHg, mmHg |
measurement range | Gauge pressure: -0.1MPa~0MPa~...~7MPa |
accuracy class | 0.1 level, 0.2 level, 0.5 level |
stable performance | Better than 0.2% FS/year |
output signal | (4-20) mA (24V DC, two-wire system) (1-5) V (24V DC, three wire system) |
contact method | RS485 (compatible with both Modbus RTU and Anson Free Protocol) |
Power supply mode; | (10~30)V直流(通讯供电) |
Collection speed | (0.1~10) seconds/time, default 0.2 seconds/time, time can be set independently |
ambient temperature | (-30~70)℃ |
relative humidity | <90% |
atmospheric pressure | (86~106)kPa |
other | Best calibration reference environment temperature: 20 ℃± 2 ℃ |
Measure the temperature of the medium | (-40~120)℃ |
display mode | Five digit backlit display+percentage bar chart |
Protection level | IP67 |
Explosion-proof rating | Ex d IIB T6 Gb |
Overload pressure | 1.5 to 3 times the measuring range, depending on the measurement range |
software configuration | AncnView-T intelligent instrument detection software (with RS485 communication): Real time display of instrument data, automatic recording, automatic drawing of pressure curves, can be exported to Excel spreadsheets for reading, printing, and saving. |
process connection | Clamp, quick chuck, customized interface |