Products & Solutions

Products and Solutions

pressure

Wireless differential pressure transmitter ACD-Z3150

Wireless differential pressure transmitter ACD-Z3150

The ACD-3150 wireless dual flange differential pressure liquid level transmitter is a new type of digital differential pressure instrument independently developed and produced by Anson Instruments based on the introduction of the "German Endershaus (E+H) company" monocrystalline silicon differential pressure sensor. It applies Anson Instruments' advanced low-power consumption technology and software compensation technology, and key components and parts are imported. The whole machine undergoes strict assembly, testing, and aging to ensure the quality of the instrument.

This product has the characteristics of advanced design, complete variety and specifications, and easy installation and use. At the same time, it can be directly replaced with traditional 1151, 3051 and other series products during installation, making it a replacement and updated product for some old models. In order to adapt to the continuous improvement and development of domestic automation level, this series of products not only have a compact and exquisite design, but also have the function of on-site pressure display.


Main Features

display unit

Pa , kPa , MPa , psi , bar , mbar , kgf/cm2 , inH2O , mmH2O, inHg, mmHg

 

measurement range

Differential pressure: 0-1kPa to 0-4MPa

accuracy class

0.075 level, 0.1 level, 0.2 level

power supply method

Built in 1 3.6V high-performance lithium battery

Collection speed

(1~60) seconds/time, default 5 seconds/time, time can be set

stable performance

Better than 0.1% FS/year

Battery working time

Built in 3.6V high-performance lithium battery, reference conditions: (16-25) ℃

Collection speed

4 times/2 times/1 second 1 time/1 second 1 time/2 seconds 1 time/3 seconds 1 time/4 seconds 1 time/(5-10) seconds

battery life

3 years

ambient 

temperature


(-30~70)℃  

relative humidity

<90%

atmospheric

 pressure

(86~106)kPa

other  

Calibration reference environment temperature: 20 ℃± 2 ℃

Instrument working environment temperature at level 0.075: (0-50) ℃


Measure the temperature 

of the medium


Conventional: (-40~85) ℃

Wide temperature range: (-70~400) ℃ flange installation

 filled with high-temperature silicone oil


display mode

Six digit display+percentage bar chart

Protection level

IP65

Explosion-proof rating

Ex ia IICT4 Ga  

Overload pressure 

Maximum static pressure: 16MPa

Unidirectional maximum overload pressure: 16MPa

Bidirectional maximum overload pressure: 24MPa

Note: Overload pressure depends on the range of measurement