pressure

Wireless pressure transmitter ACD-LR
Wireless pressure transmitter ACD-LR
Wireless pressure transmitter ACD-LR
Wireless pressure transmitter ACD-LR
Wireless pressure transmitter ACD-LR
Wireless pressure transmitter ACD-LR

Wireless pressure transmitter ACD-LR

The ACD-LR wireless digital pressure transmitter mainly consists of a pressure sensor, signal processing circuit, central processing unit, and wireless communication circuit. It integrates three popular industrial wireless communication methods: ZigBee, LoRa, and NB IoT, using advanced low-power devices and sophisticated software management technology. It has a priority processing mechanism for data alarms, data bursts, instrument failures, battery alarms, etc., ensuring real-time data monitoring and instrument status. It is powered by a large capacity high-performance lithium battery and can work continuously for 2-5 years. Realize remote real-time monitoring, wireless transmission, no need for on-site wiring, saving the trouble of on-site wiring for ordinary instruments, and saving manpower and construction costs. This instrument has advanced design, complete variety and specifications, and is easy to install and use, making it an ideal upgraded product for traditional pressure transmitters.

Main Features

display unit

Pa , kPa , MPa , psi , bar , mbar , kgf/cm2 , inH2O , mmH2O, inHg, mmHg

measurement range

gauge pressure:-0.1MPa~0MPa~...~260MPa

differential pressure:0~500Pa~...~3.5MPa

Absolute pressure:0~0.035MPa~...~60MPa

accuracy class

0.05 level, 0.1 level, 0.2 level, 0.5 level

power supply method

Built in 1 3.6V high-performance lithium battery

Collection speed

(1~60) seconds/time, default 5 seconds/time, time can be set

stable performance

Better than 0.1% FS/year

Battery working time

Built in 3.6V high-performance lithium battery, reference conditions: (16-25) ℃

Collection speed

Once per second; 1 time/2 seconds  1 time/3 seconds  1 time/4 seconds  1 time/5 seconds  1 time/6 seconds  1 time/(7-60) seconds

battery life

3 years

ambient temperature

(-30~70)℃  

relative humidity

<90%

atmospheric pressure

(86~106)kPa

other

Calibration reference environment temperature: 20 ℃± 2 ℃
0.05 Level instrument working environment temperature: (0-50) ℃ 

Measure the temperature of the medium

routine(-40~120)℃

wide temperature(-60~150)℃

display mode

Five digit display+percentage bar chart

Protection level

IP65

Explosion-proof rating

Ex ia IICT4 Ga  

Overload pressure

1.5 to 3 times the measuring range, depending on the measurement range

process connection

Public  Production: M20 × 1.5, M14 × 1.5, M14 × 1, etc. English/American standards: G1/2, G3/4, G1/8, G3/8, NPT 1/2, NPT 1/4, NPT 1/8, etc